The Alpha 36S is a clean-face traditional looking fireplace, removing the conventional framed face offers an unobstructed view of the fire that provides the
most realistic classic wood burning look available, and the benefit of enhanced radiant heat and efficiency. The Alpha 36S comes with the Komfort Kontrol
remote. The Alpha 36S is available in an arched or rectangular opening and has multiple design options to customize your fireplace.
Kozy Fireplaces : Alpha
Finish Options
Décor Design screen front with
Herringbone refractory and
optional Diamond andirons
Alpha Front
Arched Mission Design screen front with
Traditional Brick refractory and optional
Circle andirons
Options and Specifications
Alpha TOP
Alpha FRONT
Alpha LEFT SIDE
Refractory Options
Alpha Front
Arched Décor Design screen front with
Traditional Brick refractory and
aoptional Circle andirons
Alpha Front
Rectangular Mission Design screen front
with Herringbone refractory
and optional Diamond andirons
Clearances
Vent System Approval & Requirements
This fireplace is manufactured to accept 5”x 8” pipe only.
• Simpson Dura-Vent™ DV-PRO Pipe - 5”x 8”
• Selkirk Metalbestos™ Direct Chimney System -
5”x 8”
• Ameri-Vent/American Metal™
Direct Chimney System - 5”x 8”
• Metal Fab™ 5”x 8”
• Security™ 5”x 8”
• ICC™ 5”x 8”
• Kozy Heat™ Flexible #800 series
Vent Kits* - 5”x 8”
• BDM™ Direct Vent Chimney System - 5”x 8”
• RLH™ Direct Vent Chimney System
(vertical only) - 5”x 8”
IMPORTANT: Kozy Heat part #800-WPT or #800-WPT2, must be used on ALL Horizontal vent runs. The included Horizontal Vent Heat Shield must be installed when incorporating minimum horizontal venting.
This applies to NG and LP minimum horizontal venting configurations.
Elbows: For each additional 90º elbow used after the first elbow, 3’ must be subtracted from the maximum venting allowed. For each additional 45º elbow used after the first elbow, 1½’ must be subtracted from the maximum venting allowed.
Note: (2) 45º elbows = (1) 90º elbow.
Horizontal Terminations:
Minimum: 18” min vertical rise + 90º elbow + 9” minimum +vent cap
Maximum: 18” min vertical rise + 90º elbow + 20’ maximum +vent cap.